On moderate and high wildfire parcels, the code moves down from the roof to the walls, eaves, decks and windows.

Veteran-owned Family-run since 1990 650+ Google reviews

On Colorado wildfire parcels mapped as moderate or high fire intensity, the 2025 Colorado Wildfire Resiliency Code requires siding, eaves, decks, windows and doors to resist flames and radiant heat, not just embers. Siding must be noncombustible, fire-retardant-treated wood or a tested ignition-resistant material; eaves and the back of fascia must be protected; deck surfaces must meet a fire rating; windows must be tempered or multi-pane; and 6 inches of metal or noncombustible flashing goes at the ground, deck and roof lines. On an existing home these rules apply when 25 percent or more of the exterior wall area is replaced. This page is general information; Integrity Roofing and Painting does not sell or build decks, and your building department decides what passes.

On this page: When the wall rules apply · Siding options · Eaves · Decks · Windows and doors · Planning

When the wall rules apply

The state code splits mapped parcels into two hardening levels. Low fire intensity parcels follow Class 1, which covers the roof, valleys, gutters and vents. Moderate and high parcels follow Class 2, which adds everything on this page. For existing homes, section 101.7 sets the trigger: replacing 25 percent or more of total exterior wall area, or work that effectively replaces the wall material, means all exterior walls and attachments must meet the new-construction wall rules, and the 5-foot immediate zone around the house must be brought into compliance. Painting and staining are exempt. Our Colorado Wildfire Resiliency Code guide explains how the map class is set and how to challenge it.

Siding: what the code accepts

Section 404.3 lists six ways to build a compliant exterior wall, from a 1-hour fire-resistance-rated assembly to heavy timber or log walls. For most re-siding jobs the practical choice is the exterior covering, which section 404.3.1 limits to:

Covering typeCommon examples (confirm per product)Paperwork to ask for
NoncombustibleFiber cement, stucco, brick, stone veneer, metalManufacturer’s noncombustibility data
Fire-retardant-treated woodTreated wood siding labeled for exterior useLabel showing it meets 2024 IBC section 2303.2
Ignition-resistant materialProducts tested to the section 402.4 standardLabeled 30-minute ASTM E84 or ASTM E2768 results
VinylOnly over a 1-hour rated or approved noncombustible wallThe wall assembly rating

The covering must run from the top of the foundation to the underside of the eave or roof sheathing. Section 404.3.2 adds a detail inspectors look for: at least 6 inches of metal or noncombustible flashing set vertically between the sheathing and the cladding at the ground, deck and roof intersections, while still letting the wall drain. The Colorado State Forest Service gives related advice for any WUI home: keep 6 inches of vertical clearance between the ground and the siding.

If your fiber cement siding is sound, a fresh coat is maintenance the code exempts; see our Hardie board painting page.

Eaves, soffits and fascia

Section 404.2 requires the exposed underside of eaves and soffits to be protected with noncombustible or ignition-resistant material, or approved alternatives such as 5/8-inch Type X drywall rated for the purpose, 2-inch nominal lumber, or exterior fire-retardant-treated wood or plywood. Fascia is required, and its back side must be protected the same way. Soffit vents need to meet the vent rules; see our ember-resistant vents guide.

Decks

Integrity does not sell, build or repair decks, but decks sit against the house, so they are part of any hardening plan. On moderate and high parcels, section 404.5 requires the walking surface of an unenclosed deck to be one of:

  • Approved noncombustible material.
  • Class A rated material, or composite decking rated at least Class B.
  • Exterior fire-retardant-treated wood meeting 2024 IBC section 2303.2.
  • Ignition-resistant material tested to section 402.4.

NFPA’s Firewise guidance also recommends screening or boxing in the space under decks with wire mesh and removing anything stored there. Talk to a deck contractor about the board ratings and framing.

Windows, doors and garage doors

  • Glazing (404.7): tempered glass, multilayered glazed panels, glass block, or a 20-minute fire protection rating.
  • Exterior doors (404.8): noncombustible, solid core wood at least 1 3/4 inches thick, or a 20-minute rating.
  • Garage doors (404.9): gaps at the head, sill and jambs no wider than 1/8 inch, using qualifying weather-stripping, door overlaps or metal flashing.

Planning a re-side

  1. Confirm the parcel’s fire intensity class; the wall rules only apply on moderate and high.
  2. Measure whether the job crosses 25 percent of total wall area.
  3. Pick a covering and collect its test paperwork before ordering.
  4. Detail the 6-inch flashing at grade, deck and roof lines in the contract.
  5. Plan the 0 to 5 foot zone work, which a re-side pulls in. Our defensible space zones guide explains it.

If you are re-siding because of damage, our guides to hail-damaged vinyl siding, hail on fiber cement and wood, water behind siding, fiber cement clearances and deck ledger leaks explain what to fix while the wall is open.

The roof side of the house is covered in our Class A roof guide, and the whole checklist is in the wildfire home hardening guide.

Where we fit

Integrity Roofing and Painting is veteran-owned and family-run since 1990, an Owens Corning Platinum Preferred roofing contractor with 650+ Google reviews. We install roofs, gutters and siding and handle exterior painting across the Front Range, from Golden and Morrison to Monument and Woodland Park. Call (719) 488-2800 for a free Colorado Springs inspection, or (303) 209-0152 for a free Denver inspection.

Sources: 2025 Colorado Wildfire Resiliency Code, sections 101.7, 402 and 404 (DFPC); Colorado State Forest Service, Protect your home and property; NFPA, Preparing homes for wildfire.

Frequently Asked Questions

Can I use vinyl siding in a Colorado wildfire area?

On moderate and high fire intensity parcels, Colorado's wildfire code limits exterior wall coverings to noncombustible materials, fire-retardant-treated wood or ignition-resistant materials. Vinyl is allowed only as an exception, when the wall itself is built as a 1-hour fire-resistance-rated assembly or with approved noncombustible materials. On low intensity parcels the wall rules in section 404 do not apply.

What does ignition-resistant material mean in the Colorado wildfire code?

Section 402.4 defines it by testing. The material must be tested on both faces in an extended 30-minute ASTM E84 or UL 723 tunnel test, or under ASTM E2768, show a flame spread index of 25 or less, keep the flame front within 10 feet 6 inches of the burner, keep that performance after weathering, and carry labeling with its test results. Materials that melt, drip or delaminate enough to interrupt the flame front do not qualify.

What deck boards does the Colorado wildfire code allow?

On moderate and high parcels, section 404.5 requires the walking surface of an unenclosed deck to be approved noncombustible material, Class A rated material, composite decking rated at least Class B, exterior fire-retardant-treated wood, or ignition-resistant material under section 402.4. Ask the manufacturer for the rating paperwork for the exact board.

Do I need new windows to meet the wildfire code?

Only when the code applies to the work. On moderate and high parcels, section 404.7 requires exterior windows, glazed doors and skylights to be tempered glass, multilayered glazed panels, glass block, or rated for at least 20 minutes of fire protection. The Colorado State Forest Service recommends tempered glass with two or more panes for any home in the wildland-urban interface.

Start With a Free Roof Inspection

Honest findings, photos of what we see, and clear options before you commit to anything. We'll reach out the same business day.

Veteran-owned Family-run since 1990 Owens Corning Platinum 650+ Google reviews No obligation Financing available

Prefer to talk? Call (719) 488-2800

Request Sent!

Thanks. We'll review your request and reach out with the next step. For faster help, call (719) 488-2800.

We'll reach out the same business day. Your info stays with us, never sold or shared.